As seasonal temperatures decline and greenhouses are closed up to retain heat, humidity management becomes increasingly difficult. Excess moisture can produce condensation on plant surfaces, prolonged leaf wetness, uneven temperatures and greater disease pressure. Yet venting heavily to dry the house wastes energy and creates sharp temperature fluctuations, so growers have to balance heat, ventilation and air movement.
Condensation, not relative humidity, is the real target
Relative humidity on its own does not determine whether condensation will form. Condensation develops when plants or greenhouse surfaces cool to the dew point of the surrounding air, the temperature at which relative humidity reaches 100%. During cool weather, glazing, structural components and crop surfaces can become cooler than the air, allowing free moisture to form on leaves and creating conditions conducive to foliar disease. For that reason, humidity management is less about holding a specific relative humidity reading and more about preventing condensation and the leaf wetness that follows it.
Moisture accumulates overnight in a sealed house
Warm air can hold more water than cool air. During the day, crops and substrate release moisture into the greenhouse through evapotranspiration. As temperatures fall overnight, relative humidity rises and the potential for condensation increases. Because greenhouses are typically kept closed to conserve heat in cool weather, that moisture accumulates inside the structure; without adequate air movement and ventilation, the air can approach saturation by morning, particularly in cool, stagnant areas of the house.
Pairing heat with short venting cycles
Heating and venting may look like opposing actions, but they can be effective when used together. Heating raises the air temperature and lowers relative humidity, which gives moisture an opportunity to evaporate from plants and greenhouse surfaces. Ventilation then exchanges the warm, moisture-laden greenhouse air with cooler outside air, a step often described as burping the greenhouse. Used strategically, heat-and-vent cycles can remove moisture while limiting the energy loss associated with leaving vents open for extended periods.
Evening out microclimates with horizontal airflow
Greenhouse climates are rarely uniform. Microclimates with cooler temperatures and higher humidity can develop near sidewalls, corners, doors, curtains and within crop canopies. Horizontal air flow (HAF) fans help mix air throughout the greenhouse, reducing the temperature and humidity differences between these areas, and consistent air movement also helps moisture evaporate from plant surfaces.
The guidance notes one limit to that tool: HAF fans do not remove moisture from the greenhouse. Air movement therefore needs to be combined with appropriate ventilation when moisture levels become excessive.
Ball Seed, a North American wholesale horticultural distributor, said growers can find further detail on cold-weather humidity management, including crop management through environmental controls and better balancing of energy load, in its Technical Services blog.